Cooling Water Treatment Chemicals

Catalyst Chem provides the best combinations of cooling water treatment programs. These specially designed coolingwater treatment programs help protect your cooling systems from scalling, corrosion and microbiological growth.

Passivation Chemicals

These chemicals are used in cooling towers to create a passivation layer before the stgart up of the cooling tower treatment program. These chemicals are generally used in a new system or in an existing system after the system cleaning process.

Catalyst Chem’s cooling tower passivation chemicals include CW 102, CW 105 & CW 108.

Bio Dispersants

These chemicals are used to disperse the micro organisms in the cooling water systems. Once dispersed into the cooling systems, the biocides can then act and kill the micro organisms. These chemicals prevent bio films from forming in the cooling systems.

Catalyst Chem’s Clooling tower bio dispersants include CW 301, CW 303 & CW 304 .

Multifunctional Product

These chemicals contain a mixture of corrosion inhibitors and scale inhibitors & are very effective to control scaling and corrosion in cooling systems.

Catalyst Chem’s cooling tower multifunctional chemicals include CW 453 & CW 454.

Oxidising Biocides

These chemicals are used to control the formation of bacteria, algae, fungi & various other micro organisms which can occur in a cooling water system. Catalyst Chem provides different ranges of oxidising biocides depending upon the nature & degree of the microbiological growth in the system.

Catalyst Chem’s cooling tower oxidising biocides include CW 111 (solid chlorince biocide). CW 112, CW 115 (precursor for chlorine dioxide) & NS 1530.

Non Oxidising Biocides

These chemicals are used to control the formation of bacteria, algae, fungi & various other micro organisms which can occur in a cooling water system. Catalyst Chem provides different ranges of non oxidising biocides depending upon the nature & degree of the microbiological growth in the system.

Catalyst Chem’s non oxidising biocides include CW 401, CW 402, CW 403 (algaecide) & CW 405.

Anticalents & Mineral Dispersants

These chemicals are closed in the cooling tower to prevent scaling from happening in the cooling systems. Iron, Silica, etc. Catalyst Chem has various combinations of the best quality antiscalent and minieral dispersants available to address scaling issues in your system.

Catalyst Chem’s cooling tower antiscalents include CW 201, CW 202, CW 211 & CW 212.

Cooling System Descaling Compounds

These chemicals are used as cleaning agents for scaled up cooling systems. Catalyst Chem offers different descaling compounds depending on the nature of scale & the metallurgy present of the system.

Catalyst Chem’s cooling system descaling chemicals include NS 1940 & DC 420.

Hot Water Corrosion Inhibitors

These chemicals are closed to prevent corrosion from happening in systems where water temperature is on the higher side (55 - 80) degrees celsius. Corrosion rate increases with the increase in temperature and these chemicals are closed to provide sstrong corrosion protection in such systems.

Catalyst Chem’s hot water corrosion inhibitors include CW 619 & CW 620.

Chilled Water & Close Loop Corrosion inhibitors

These chemicals are generally nitrite/molybdate/silicate/organic based chemicals which are closed in chilled water circuits to prevent corrosion from happening in such systems.

Catalyst Chem’s close loop corrosion inhibitors include CHW 011, CHW 013 & CHW 015.

Yellow Metal Corrosion Inhibiors

These chemicals are closed in the cooling towers to prevent corrosion from happening in the Copper/Amiralty Brass/Cupro Nickel pipelines & other parts of the cooling systems. These corrosion inhibitors are azole based chemicals.

Catalyst Chem’s Yellow metal corrosion inhibitors include CW 666 & CW 667.

Mild Steel & Stainless Steel Corrosion Inhibitors

These chemicals are closed in the cooling towers to prevent corrosion from happening in the MS/SS/GI pipelines & other parts of the cooling systems. These chemicals are generally Zinc & Orthophosphate based.

Catalyst Chem’s MS & SS corrosion inhibitors include CW 609, CW 608 & CW 102 .

Alkalinity Reducers

These chemicals are closed in the cooling water system to maintain the pH of the recirculating water.

Catalyst Chem’s cooling tower alkalinty reduces include PR 845, PR 846 & PR 848.